Posts Tagged ‘hvac’

hotted up, the sequel

Monday, December 5th, 2011

If you’ve been following along, the new heat was installed a week or so ago. Then came time to get it running. Jeff from RAM Mechanical came back to commission the HVAC system. First he checked that the 100 psi of nitrogen he put in the lines hadn’t leaked out…

hvac1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Next he double-checked all the wiring. Once he was sure everything was good to go, he turned it on. There was a problem with the amount of refrigerant in the compressor — it was charged assuming 150′ of pipe but we only had 52′, so the pressure got too high and everything shut down. A couple of phone calls later we had the right amount of pressure and things were heating up nicely.

Until we start on the upstairs construction and tear out the old electric baseboard, these two thermostats will be neighbors. 1971 meet 2011…

hvac2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The new thermostat is also a remote control… or is it a remote control that’s also a thermostat? It has all the features you might want except it’s not programmable to automatically reduce energy use during different times of the day…

hvac3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

It does have a night-time setback mode which gradually reduces energy use (raising the temp in cooling season, lowering the temp in heating season), but it’s manual mode. We’ll see if there are any other thermostat options available for this system.

In any event, the new Sanyo units produce plenty of heat, the fans are very quiet even on high, and we can’t hear the compressor run. So far so good, we’ll see what the electric bill has to say next month.

hotted up

Monday, November 28th, 2011

Let’s talk briefly about how we’re going to heat our house. Currently, we have electric baseboard heat. It’s actually fairly efficient — it converts about 95% of the electricity into heat. But we’re investing in something even more efficient — and, key to a small house like ours, it allows us to use all the wall space that’s currently taken up with heaters.

So what is this wonder of which I speak? Officially known as an air-source heat pump, you may have heard it called a “mini-split.” Chances are you’ve seen one as the A/C-only units are popular in restaurants. This is the Sanyo unit we’ll be using (comes with a handy-dandy remote)…

KMHS0772-48857444 via sanyo.com

 

 

 

 

 

If you want a really good explanation of why it’s more energy efficient, you should read this. So our new heat pump was installed a few days ago…

hvachookup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With some aesthetic changes and the elimination of the dark purple paint, eventually that mildly unattractive white rectangle above the window will disappear from view. We hope.

There are two refrigerant lines, the electric cable and a small PVC drain line for any condensation that forms in the summer or in winter when the unit is in defrost mode. The connections run down inside the double wall…

hvac1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The hoses exit outside where they travel inside a piece of PVC over to the compressor…

hvac2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I’ll clean up that expanding foam and seal a piece of metal flashing over the hole to maintain our water and air infiltration integrity, and to keep out 4- and 6-legged vermin.

An outside unit (the compressor) takes heat out of the air and pumps it into refrigerant which is circulated through pipes to the indoor unit (in summer the process is reversed)…

 

hvac4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The compressor is relatively small considering it provides 32,000 BTUs of heat — and 34,000 BTUs of cooling. It can support up to four connections. We’ll be using just two: a 9,000 BTU unit downstairs and a 24,000 BTU unit in the upstairs living area. Each is connected to the compressor with two copper refrigerant lines wrapped in black foam insulation, and a 3-wire cable carrying electricity to the fans in the inside unit. The wire also carries signals from the inside units back to the compressor telling it whether to send heat or cooling, and how much to send. The compressor has a variable-speed DC motor which can run faster or slower as needed to suit demand. This makes it much more efficient than a simple on/off compressor.

Now that our electrician has made all the wiring connections, RAM Mechanical (our HVAC installer extraordinaire) will return to double-check the refrigerant connections for leaks. Before they left, they filled the hoses with nitrogen under pressure. If the pressure has dropped over the last week they’ll know something is amiss. Hopefully this is just a precaution and later this week we’ll have heat! In a month or two we’ll compare our past electric bills to the current ones and know just what we’re saving with the new system.